40 88 40 16.5 24.5 3/8 29 32 77.5 35 64 52.5 71.5 28 77.5 69.5 69.5 57.5 104.5 71.5 73.5 5 10 13 XSA-OMS0001-A 4.
Description Applicable model Material Note AW20 to 60-B Urban white Body Aluminium die cast AW20 to 40-B Polyacetal Bonnet Urban white AW60-B Aluminium die cast Option / Replacement Parts Option Material Part No. Thread No.
dripping flow rate Note 1) 15 L/min (ANR) Port size 1/4: 30 L/min(ANR) Port size 3/8: 40 L/min(ANR) Oil capacity 25 cm3 55 cm3 135 cm3 Recommended lubricant Class 1 turbine oil (ISO VG32) Bowl material Polycarbonate Bowl guard Semi-standard (Steel) Standard (Polycarbonate) Weight 0.10 kg 0.18 kg 0.37 kg 0.41 kg 0.92 kg 0.99 kg Note 1) The flow rate is 5 drops/min under the following conditions
Example: The figure below is based on the condition of set values as P1 = 40 [kPa] and P2 = 20 [kPa].
Bracket assembly 15 7-2. Auto drain replacement 15 7-3. Element replacement 19 8. Dimensions 20 -2- Doc. no. AMX-OMU0058-C Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.
(Stroke) IN OUT (125) (102) C B A Rc1 DRAIN 195 (270) Dimensions (mm) A B C D Model Bore size (Nominal size B) FN11l1 FN11l2 610 (730) (844) 20 Rc1 860 (1000) (1134) 40 9 Low Maintenance Filter Series FN1/FN4 Dimensions: FN4 330 0 90 270 225 180 Pressure gauge port size Rc1/4 G46-15-02M Head end cylinder port Rc3/8 Rod end cylinder port Rc3/8 (Manual lock release) Dustproof cover Unlocking
15 0 70 20 20 0 10 20 30 40 50 60 70 80 0 20 40 60 80 100 120 140 160 180 Time (minute) Time (minute) Pressure Loss in FacilityWater Circuit The values shown on the performance chart are not guaranteed, but typical.
D-M9B D-M9N, D-M9P D-A93 Load voltage Load current range Indicator light Application 24 VDC (10 to 28 VDC) 28 VDC or less 24 VDC, 100 VAC 2.5 to 40 mA 40 mA or less 5 to 40 mA, 5 to 20 mA 24 VDC relay, PLC IC circuit, Relay, PLC Relay, PLC Solid state auto switch PLC: Programmable Logic Controller Refer to page 920 for the applicable auto switch list. 905 Rotary Actuator 11-CRA1-Z Rotation
to 100 mm2/s Hydraulic fluid 40 to 100 mm2/s DIN terminal DIN terminal with light/surge voltage suppressor Caution CE-compliant This product cannot be used for water application.
(mm) Model Flange Note) Kv Conversion Cv Rc VND10D-6A VND10D-8A VND10D-10A VND20D-10A VND20D-15A VND30D-20A VND40D-25A VND50D-32A VND50D-32F VND60D-40A VND60D-40F VND70D-50A VND70D-50F 0.9 1.0 1.1 4.3 4.6 8.6 13.6 1.1 1.2 1.3 5.0 5.4 9.9 16 1 8 1 4 7 0.3 3 8 15 0.6 1 2 3 4 20 0.9 1.4 2.3 5.5 3.6 7.2 5.7 25 1 1 4 1 15.7 18 32 32 1 2 1 32.9 38 40 40 2 53.6 50 62 10.8 50 Note) The companion
20 17 22 19 K 5 8 8 8 8 L 9 12 12 14 14 N 35 40 40 50 50 O 54 66 66 80 80 P 70 84 84 100 100 Q 26 28 28 34 34 R 4.5 5 5 5 5 S 1.6 2.0 2.0 2.3 2.3 5.5 6 6 7 7 AME150 1 8 1 4 3 8 139 152 158 184 190 13 13 16 16 19 55 66 72 92 98 63 76 76 90 90 7.5 4 4 5 5 63 76 76 90 90 10 10 10 10 10 , , 1 4 3 8 , AME250 1 2 3 8 1 2 , AME350 3 4 14-20-40 5 Super Mist Separator Series AME AME450 to AME850
General 3 positions 5 positions General 15 Setting (continue) 1.Stroke adjustment General 3 positions 5 positions General Adjust the stroke of actuating part. 1-1 Loosen fixing bolt, move the unit to the position where required stroke is obtained and fix the unit by the bolt. 1-2 E-MY2C/H Loosen lock nut for adjusting bolt for fine setting of stroke by the bolt.
31 105 93 66 1/4 47.5 23.5 65.5 6 M4 x 0.7 Depth 4.5 22 29 0 38 40 31 125 66 1/4 23.5 82.5 23 67.5 10.5 M4 x 0.7 Depth 4.5 22 29 0 38 40 31 125 66 1/4 23.5 84.5 27.5 M5 x 0.8 Depth 5 24 28 2 43 48 36 112 100 76 3/8 50.5 27.5 68.5 M5 x 0.8 Depth 5 24 28 2 43 48 36 132 76 3/8 27.5 85.5 16 70.5 3.5 M5 x 0.8 Depth 5 24 28 2 43 48 36 132 76 3/8 27.5 87.5 20.5 M6 x 1 Depth
Nominal10 ) Square embedded pressure gauge Applicable model Process Procedure Tools Check items Disassembly Remove the pressure gauge cover Rotate the pressure gauge cover 15 counterclockwise to pull out the pressure gauge cover.
B: Locking slotted type 4 1 6A 8A 10A 10A 15A 20A 25A 32A 40A 50A 1 8 1 4 3 8 3 8 1 2 3 4 220 VAC 50/60 Hz 10 5 6 24 VDC 12 VDC 240 VAC 50/60 Hz 7 15 2 9 Other Nil: Non-locking push type 20 3 Option Valve size 5 to 7 25 4 1 1 1 2 32 5 1 4 1 2 40 50 6 7 Note) Air operated only Electrical entry/ With light/surge voltage suppressor E GS G Grommet with surge voltage suppressor Grommet Grommet
General 3 positions 5 positions General 15 Setting (continue) 1.Stroke adjustment General 3 positions 5 positions General Adjust the stroke of actuating part. 1-1 Loosen fixing bolt, move the unit to the position where required stroke is obtained and fix the unit by the bolt. 1-2 Loosen lock nut for adjusting bolt for fine setting of stroke by the bolt.
at 40 mA) Current leakage 100 A or less at 24 VDC Indicator LED Red LED illuminates when turned ON.
31 105 93 66 1/4 47.5 23.5 65.5 6 M4 x 0.7 Depth 4.5 22 29 0 38 40 31 125 66 1/4 23.5 82.5 23 67.5 10.5 M4 x 0.7 Depth 4.5 22 29 0 38 40 31 125 66 1/4 23.5 84.5 27.5 M5 x 0.8 Depth 5 24 28 2 43 48 36 112 100 76 3/8 50.5 27.5 68.5 M5 x 0.8 Depth 5 24 28 2 43 48 36 132 76 3/8 27.5 85.5 16 70.5 3.5 M5 x 0.8 Depth 5 24 28 2 43 48 36 132 76 3/8 27.5 87.5 20.5 M6 x 1 Depth
-00 KPQL10-00 18.5 16 25 35 23 6.8 28.4 M L 8 12 KPGL12-00 KPQL12-00 20.9 20 40 50 24 7.5 30.4 Note 1) D indicates the maximum diameter.
ANA1-C08 11 5 58 16 ANA1-C10 15 13 76 22 ANA1-C12 33 19 95 25 Series Construction/Parts/Dimensions Symbol Noise reduction A1 40 dB (A) ANA1-C08 to C12 Case (PBT) (PVT) (PBT) End plate Sound absorbing material Specifications Max. operating pressure Note) Fluid Compressed air 1.0 MPa 40 dB (A) 5 to 60C Noise reduction Ambient and fluid temperature Note) It indicates the inlet pressure for solenoid