mm, Width: .79 in / 20 mm, Height: .81 in / 20.5 mm, Net Weight: .07 lbs. / .03 Kg Series Configured Datasheet.
Body Size: 3 (3/8), Type: 2 (Elbow), Control Type: 0 (Meter-out), Model: 1FS, Thread: N (NPT), Port Size: 03 (3/8), Width Across Flats: 9 mm (or None: Sizes 2/3/4), Applicable Tubing: 07 (ø1/4"), Seal: S (with Sealant)
Type of Connector: F (D-sub Connector 25 Pin), Connector Outlet Direction: 2 (Connector Side Direction), Stations: 11 Stations, SUP/EXH Block Mounting: B (Both Sides 2~20 Stations), Pilot: RS (External Pilot, Silencer), A, B Port: 03 (Rc3/8)
Valve Stations: 2 Stations, Port Size: 03 (3/8), Thread: F (G), SI Unit: V (CC-Link), End Plate Type: 2 (M12 Connector Power Supply, Max Supply Current 2A), SI Unit COM: N (-COM)
Stations: 03 Stations, Port Size: C6 (w/ø6 One-touch Fitting), SI Unit: Q (Device Net), End Plate: 2 [Power Supply w/M12 Connector (Max. supplied Current 2 A)], SI Unit Common: N (-COM)
Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 3 (Common), Pressure Specification: Standard (0.7MPa), Coil Specification: T (Power Saving Circuit, DC Only), Voltage: 5 (24VDC), Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: D (Push-turn Locking Slotted Type), Port Size: 03 (3/8), Thread: N (NPT
Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 3 (Common), Pressure Specification: K (High-pressure, 1MPa), Coil Specification: T (Power Saving Circuit, DC Only), Voltage: 5 (24VDC), Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: D (Push-turn Locking Slotted Type), Port Size: 03 (3/8), Thread:
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: BT (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: PNP; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: F (Instantaneous Flow: gal/min, Accumulated Flow: gal, Temperature: °F), Bracket
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: L2T (Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature
Valve; w/Stop Valve), Return Port Size: 03 (3/8), Flow Switch Output Specifications: B (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Stations: 4 Stations (Note: 2 Stations are Required for Terminal Box Mounting), Port Size: 03 (Rc3/8), Thread: Rc (PT), Kit Name: T (Terminal Box), Box Mounting Position: 0 (U Side Mounting), Control Unit: None, Release Valve Rated Voltage: w/o Air Release Valve, Option 1: N (Name Plate), Option 2: W (IP65 Protection Compatible)
Base Mounted Wiring: 01T (Base Mounted Plug-in w/Terminal Blocks), Stations: 2 Stations, Passage: 2 (P and EA,EB: Common, Port A,B: Bottom), Port Size: 03 (3/8)
Valve; w/Stop Valve), Return Port Size: 03 (3/8), Flow Switch Output Specifications: B (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Body Size: 40, Thread: F (G), Port Size: 03 (3/8), Option: D (N.O., Float Type Auto Drain), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard
Type of Actuation: 2 (2 Position Double), Manifold Type: 40 (Base Mounted), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: D (Push-turn Locking Slotted Style), Port Size: 03 (Base Mounted w/Sub-plate 3/8), Thread: T (NPTF)
Type of Actuation: 2 (2 Position Double), Manifold Type: 40 (Base Mounted), Pilot: Internal Pilot, Specifications: Standard, Voltage: 3 (110VAC 50/60HZ), Electrical Entry: G (Grommet Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: None, Manual Override: Non-locking Push Style, Port Size: 03 (Base Mounted w/Sub-plate 3/8)
Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: G (for Sizes 20, 25, 30, 40 Round Type Pressure Gauge w/Limit Indicator; for Size10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: TV (T + V), Semi-Standard 1: 23 (2 + 3), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Base Mounted Wiring: 01FD (Plug-in w/D-sub Connector on D Side), Stations: 2 Stations, Passage: 2 (P: Common, EA,EB: Common, Port A,B: Bottom), Port Size: 03 (3/8), Thread: T (NPTF)
Stations: 10 Stations (Note: 2 Stations are Required for Serial Unit Mounting), Port Size: 03 (Rc3/8), Mounting Base: S (U Side), Kit Type: Q (DeviceNetâ„¢, 16 Output Points), Option 1: None, Option 2: W (Dust Poof IP65 Rated)