4.2 M5 X 0.8 M22 X 1.5 20 23.5 29.5 36 5 37.5 43.5 50 6 Plug Mounting Style CJPS B C E G H K MM NN 5st 10st F 15st R 5st 10st S 15st W Q 5st 10st Z Bore (mm) 6 10 15 A 15st 7 12 13.9 6 12.5 19.5 26.5 8.5 9 3.5 M3 X 0.5 M10 X 1.0 9 18.5 25.5 32.5 3 27.5 34.5 41.5 3 10 19 22 6 14.5 21 28 12 12 3.5 M4 X 0.7 M15 X 1.5 13 20.5 27 34 4 32.5 39 46 5 12 27 31 7 16.5 22.5 29 19 14 4.2 M5 X 0.8 M22
When the cylinder is operated with any part removed, malfunction will occur and it is very dangerous. c. Although fittings with sealant are used for pipe fittings and switch mounting plugs, wind them with pipe tape to prevent air leakage when reassembling after position changes. d.
valve Measurement distance: 1m R(PT) R(PT) M3 M5 1 8 1 8 Port size Fluid Noise reduction dB(A) 16 21 13 18 Compressed air Max. operating press Ambient and fluid temperature 1.0MPa 5 to 50C Effective area (mm2) Weight (g) Dimensions (mm) 20 35 1 5 9.5 20 1 3.3 22.5 38 9 17 11 A B 13 6 8 Note) NPT thread for AN101 and AN110 is alsoavailable.
(Values at the initial period) VQZ VZ VS VFN Base mounted Flow Characteristics/Weight Weight (kg) Flow characteristics P A Port size Rc C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv A E AC 0.34 0.34 0.40 0.40 0.32 Body type Valve model DC 0.46 0.46 0.52 0.52 0.44 VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00 1 8 1 4 1 4 3 8 2.5 3.6 3.2 3.6 0.39 0.34 0.31 0.18 0.86 0.86 0.93 0.94 0.66 0.88
Current A Pin plug shape Applicable cable (Cabtire cable) 0.75 mm2, 1.25 mm3/2 core, 3 core (O.D. 6.8 to 11.5) based on JIS C 3312 and C 3322. Outlet changing procedure To change the wire outlet, first separate the terminal cover from the terminal block.
Pin plug shape Applicable cable (Cabtire cable) 0.75 mm2, 1.25 mm2/2 core, 3 core (O.D. 6.8 to 11.5) based on JIS C 3312 and C 3322. Outlet changing procedure To change the wire outlet, first separate the terminal cover from the terminal block.
Leakage voltage Caution Take note that the leakage voltage will increase when a resistor is used in parallel with a switching element or when a C-R circuit (surge voltage suppressor) is used for protecting a switching device because of the leakage voltage passing through the C-R circuit. The suppressor residual leakage voltage should be as 3% or less of the rated voltage. 3.
CUJ CU B Dimensions (without magnet) (mm) B Bore size Overall length: Maximum shortened approx. 64% Volume: Maximum reduced approx. 70% (compared to series CU cylinder without magnet) C A B 4 6 8 10 13 (13) 15 19 (22) 13 13 (33) C + Stroke C + Stroke 13 13.5 (15) 21 22 (24) 13 13 (36) A A 10 Dimensions inside ( ) are for series CU cylinder. 1 in 25.4mm Uses new type miniature auto switches
IS400-1 (1S-1) IS400-2 (1S-2) Model Port size B J A C D E F G H I , 1 4 1 2 1 1 AL800-12 to 14-1 AL900-20-1 431 (481) 437 (487) 3 x M5 x 0.8 x depth 6 3 x M5 x 0.8 x depth 6 230 230 ( ): With float switch 117 117 60 60 100 100 2 59 63 166 162 73 73 1046
x 0.8; T1 type: NPT 1/8, M5 x 0.8 Front case: PBT; Rear case: PBT; Piping port: C3602 (electroless nickel plated) Sensor pressure: Silicon; O-ring: NBR Material Weight 43g (without lead wire) Note 1) When switch output is selected, analog output is not available.
Connector type (Lead wire: 3 m) CL Note) Single mounting style: M5 x 0.8 (female) threaded.
Relief port M5 thread The body material has been changed to aluminum. ITVH X234 SRH Standard model no.
mount 40 Holding screw for main air supply (M2.5) 16 Main air suppy flow adjustment screw Initial air supply flow adjustment nut 11 Holding screw for initial air supply (M5) 82.5 9 MODEL M port M5 x 0.8 PRESS. 0.2MPa~10Pa 0.4~0.7MPa OPERATING PRESS IN Main air supply valve port TEMP. 5~60C S port M5 x 0.8 Initial air supply valve port MADE IN JAPAN (32) M S 52 (Body dimension) 65.8 (XVD2-
Pressure Sensor Series PSE530 How to Order PSE53 0 M5 Sensor range Option None 0 1 2 3 Positive pressure [0 to 1 MPa] Vacuum [0 to 101 kPa] Low pressure [0 to 101 kPa] Compound pressure [101 to 101 kPa] Nil Port size Sensor cable (3 m) M5 R06 R07 M5 x 0.8 6 reducer 1/4 inch reducer L ZSE ISE Option ZSP Connector for pressure sensor controller (1 pc.) + Sensor cable (3 m) Description Part
Performance Weight g Recommended flow m3/min(ANR) Effective area mm2 Sonic conductance C [dm3/(sbar)] Model AN05-M5 AN10-01 AN15-02 AN20-02 AN30-03 AN40-04 0.4 or less 0.5 5 1 1 10 2 0.8 or less 3 2.5 15 1.0 or less 4 7 35 3.0 or less 60 12 5.0 or less 5.5 90 8.0 or less 18 8.5 Note) Recommended flow rate is the flow at 72.5psi (0.5 MPa) in the inlet pressure.
SRP1-M5 SRP1-01 Pressure gauge part no.
2-Color Display Type High-Precision Digital Pressure Switch Series ZSE30/ISE30 How to Order Option 1 Without lead wire Nil Lead wire with connector (Lead wire length: 2m) L ISE30 01 25 M For positive pressure ZSE30 01 25 M For vacuum/Low pressure Option 2 Piping specification R 1/8 (with M5 female thread) NPT 1/8 (with M5 female thread) 01 T1 None Bracket Nil A Output specification NPN output
L-bracket Port size 3 3/8 Note) Note) The exhaust C port size is 1/4".
size Port 1(P), Port 2(B), Port 4(A): Rc1/8 Port 3(EB), Port 5(EA): M5 x 0.8 XT34-60 (With lock) 192 177 149.3 MOD.
Please keep this manual handy for future reference. 4 x M5 : Tightening torque: 1.5 Nm Ethernet communication cable COM A COM B COM C COM D 685 Display Description The power supply for input and control is OFF LED is OFF Operating normally Green LED is ON MS To obtain the operation manual about this product and control unit, please refer to the SMC website (URL http://www.smcworld.com) or