SMC Corporation of America
Elite Part Number Search
Search Results "VV2Q32-12-D-00N"

MDHR3-10 1122MDHR3-15 1122H L H When auto switch D-M9V is used When auto switch D-M9 is used When auto switch D-M9V is used Max. protrusion of auto switch from edge of body: L, H Max. protrusion of auto switch from edge of body: H (mm) (mm) D-M9 D-M9V D-M9V Auto switch model Auto switch model L H 1.3 The auto switch will not protrude in the case of D-M9. 2.3 H 939 Rotary Actuated Air

switch P3DWAm D-P3DWAm M9mV D-M9mVm *: For applicable auto switches, refer to the table below.

Valve model Port size L J H G F E D C A B VCW20-12-01A VCB2 1/8, 1/4 13 6 4.5 5 12.8 12.8 30 25 40 34 VCW30-12-02A 1/4, 3/8 19 7 5.5 6 19 19 40 30 52 42 VCB3 VCW30-12-04A 1/2 23 7 5.5 6 23 23 44 36 56 48 VCW40-12-02A 1/4, 3/8 19 7 5.5 6 23 23 40 30 42 52 VCW30-12-04A VCB4 1/2 23 7 5.5 6 23 23 44 36 56 48 VCW40-12-06A 3/4 26 7 5.5 6 28.2 28.2 53 44 56 65 Two mounting screws (for mounting

/Dimentions Male Quick Fastener Dimensions Table A 60.15 Port size (Quick fastener) Port size (Quick fastener) P7 P10 P7 P10 A B C D E 7 0 0.05 9.90.05 15 10 0 0.05 12.850.05 20 Clip part no. A B C D VDW30-CP7 26 7 9 14 VDW40-CP10 28 10 10 15 C D 2.50.1 9 or less 1.6 or more 2.5+0.25 0 2.5+0.25 0 D B 120.1 13 17 O-ring 2 or more O-ring dimentions P7 P10 (Nominal no.)

Repeat the same setting steps for CH2 to CH4. 16-3-12 12 Series PSE530/200 Multi-channel Controller/Pressure Sensor Operation 2: Pressure Setting Manual setting Channel selection Output mode MPa Measuring mode Hysteresis mode: Hysteresis of the switch output can be set arbitrarily.

No need of power supply for ITV Controller Electro-pneumatic regulator Power supply voltage Output signal Pressure Switch output Power supply voltage Maximum 1 4 to 20 mA 12 VDC Power supply for electro-pneumatic regulator Power supply for electro-pneumatic regulator PWR ERR Minimum Power supply 2 0 to 10 VDC 12 VDC for controller 0 3 4 to 20 mA 24 VDC OFF ON Series ITV Output signal 4 0

/A8, D-A7H/A80H, D-A73C, A80C, D-C7/C8, D-C73C/C80C, D-E7A, E80A, D-Z7/Z8, D-9/9A, D-A9/A9V, D-A79W The auto switches above do not have a built-in contact protection circuit.

of needle rotations ASN Dimensions AQ (Hexagon width across flats) (Hexagon width across flats) Applicable tubing O.D. d ASV Applicable tubing O.D. d AK VCHC ASR ASQ A (2) L4 (1) Max.

Weight Material: NBR, Mounting: A [g] qWeight Difference by Mounting Style [g] ZHP63BMNA-C6S 184 ZHP80BMNA-C6S 224 ZHP63UMNA-C6S 167 ZHP80UMNA-C6S 175 B C D E F G H 20 5 14 7 25 1 11 wWeight Difference by Material [g] For the ZHPA-00 (without ejector), weight shown above 12 g.

Select the model with air flow capacity exceeding the calculated corrected air flow from data D of the table below.

/14) A B C 1 V 1.8 V 5 V 4 mA 7.2 mA 20 mA (PF3W521-U30) A B C 1 V 1.48 V 5 V 4 mA 5.92 mA 20 mA [L/min] PF3W504 0.5 4 PF3W520 2 16 PF3W540 5 40 PF3W511 10 100 PF3W521-12/14 50 250 PF3W521-U30 30 250 () A B C D 0.6 V 1 V 5 V 5.4 V -40No.PF-OMN0009CN-F PF3W504/520/540/511 2X A AA B DD E F G H J K L N P PF3W504 3/8 70 50 30 45.6 40.6 15.2 24 14 35 26 18 13.6 2.7 14 PF3W520 3/8 1/2 78 54

6 11.6 11 6 11.6 6.3 44.8 AQ240F-07-00 AQ240F-07-07 13.7 13.7 15.4 6.2 13.7 27.3 40.7 8 10.0 15.1 6.2 1/4" 12 6 1/4" 12 40.7 AQ340F-07-00 AQ340F-07-07 16.8 20.3 13.7 16.8 7.1 52.2 33.1 20.0 13 11.8 1/4" 13.2 11 1/4" 13.2 7.1 22.2 15-12-4

Auto switch Auto Switch Specifications D-M9(With indicator light) Auto switch model D-M9N D-M9P Electrical entry direction In-line Wiring 3-wire Output NPN type PNP type Applicable load IC circuit,Relay,PLC Power supply voltage DC51224V(4.5 to 28V) Current consumption 10 mA or less Load voltage DC28V or less Load current 40 mA or less Internal voltage drop 0.8 V or less at 10 mA (2 V or less

M ast er Pow er SU P. ( D C24V) PRO FI BU SD P Sl ave1 O t her D P equi pm ent Sl ave2 O t her D P equi pm ent The pressure proportional to the signal on the second side is obtained.

ASP 10.5 35.2 39.5 14.2 8 12 R 1/8 M5 x 0.8 10.9 42.4 48.7 15 36.7 41.7 18.5 12 17 R 1/4 1/8 ASN 14.4 50 56.2 19.8 41.9 46.9 23 12 19 R 3/8 1/8 AQ 18.3 61.8 70.3 26.5 57.3 64.8 28.6 17 24 R 1/2 1/4 25.9 ASV Reference dimensions of R thread after installation.

White Load 50 OUT2 2 12 to 24VDC + Load (41.5) 3 Blue PF2W7T--67(-M) Connector pin numbers 4 3 77 34 2 1 Pin no.

Option J: With drain guide Bracket (Option) 1/4B female thread T: With element service indicator Maintenance space HA Drain AT ID AMG AFF Element service indicator Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 10 10 10 10 10 10 10 10 10 I 56 66 66 80 80 90 90 100 150 J 15 20 17 22 19 25 21 30 40 K 5 8 8 8 8 10 10 10 15 L 9 12 12 14 14 14 14 16 20 M 5.5

L4 Note) Weight (g) 3 5 5.5 6.5 8.5 9.5 19 22 36 38 42 44 76 82 Model D1 Applicable tube O.D. d AS1002F-02 AS1002F-23 AS1002F-04 AS1002F-06 AS2002F-04 AS2002F-06 AS2052F-06 AS2052F-08 AS3002F-06 AS3002F-08 AS3002F-10 AS3002F-12 AS4002F-10 AS4002F-12 D2 D3 D4 L1 L2 L3 L5 L6 L7 L8 M1 MIN. 18.4 21 21.7 22.7 25.4 26.5 28.2 29.5 33.6 34.4 36 37.1 44.1 45.1 6 8.4 9.3 11.6 9.3 11.6 12.8 15.2 13.2