Note 3) Adjust the mounting position after confirming the auto switch operation. 2 3 5 1 1 2 3.5 3 5 1 1 2 4 5 7 7 6.5 6 5.5 5 7 7 6.5 6 Auto Switch Mounting Operating Range Watchmakers screwdriver (mm) Auto switch model Applicable bore size 6 2 2 3 8 2.5 2.5 3.5 10 12 16 20 2.5 2.5 3.5 D-F8 3 2 4 4 3 4 4 3 5 D-M9 D-M9W Auto switch mounting screw This is a guideline including hysteresis,
Figures in body of chart are suggested minimum rod diameters Exposed Length of Piston Rod (IN) Tons 10 20 40 60 70 80 100 120 1/2 3/4 1 3/4 13/16 1-1/16 1 5/8 7/8 1-1/8 1-1/4 1-3/8 1-1/2 11/16 15/16 1-3/16 1-3/8 1-1/2 2 3/4 1 1-1/4 1-7/16 1-9/16 1-3/16 3 13/16 7/8 1-1/8 1-3/8 1-9/16 1-5/8 1-7/8 4 15/16 1 1-3/16 1-1/2 1-5/8 1-3/4 2 2-1/4 5 1 1-1/8 1-5/16 1-9/16 1-3/4 1-7/8 2-1/8 2-3/8 7-1/
Figures in body of chart are suggested minimum rod diameters Exposed Length of Piston Rod (IN) Tons 10 20 40 60 70 80 100 120 1/2 3/4 1 3/4 13/16 1-1/16 1 5/8 7/8 1-1/8 1-1/4 1-3/8 1-1/2 11/16 15/16 1-3/16 1-3/8 1-1/2 2 3/4 1 1-1/4 1-7/16 1-9/16 1-3/16 3 13/16 7/8 1-1/8 1-3/8 1-9/16 1-5/8 1-7/8 4 15/16 1 1-3/16 1-1/2 1-5/8 1-3/4 2 2-1/4 5 1 1-1/8 1-5/16 1-9/16 1-3/4 1-7/8 2-1/8 2-3/8 7-1/
-43S(V) P DIN terminal M L Model G 59 60 63 H 48 58.5 64 64 63 J 47 48 51 51 (Unit: inch) 1/4 1/4 1/4 3/8 8 10 10 10 3 5 5 5 XSA12S(V) XSA22S(V) XSA3-32S(V) XSA3-43S(V) 34 High Vacuum Angle Valve Series XL 1 With pilot pressure at 0.5MPa (72psi) XLA Normally closed XLC Double acting (dual operation) Valve type Model 1200 1200 1000 1000 800 800 T msec T msec 600 600 Bellows seal 400 400 200
F 3 COMPRESSED AIR THEORY Units Pressur Prooerties of Gases lsothermic change (Boyle's Law) lsobaric change Charles Law Law of Gay Lussac lsochoric change Adiabatic (lsentropic) change Standard Volume Flow Bernoulli's Equation Air Humidity Relative humidity Pressur and Flow Use of the diagram: Formulae: 6 6 I 1 0 1 0 1 1 1 1 1 1 1 1 1 2 1 2 1 2 1 2 1 2 1 3 1 5 1 6 1 6 AE 36 36 5 AIR TBEATMENT
5 5 Rated voltage [V] 24 VDC 10% Note 1) Please consult with SMC for non-standard strokes as they are produced as special orders.
ZX1-R1-1 ZX1-R1-3 ZX1-R16 4 pcs. (Ordering example) ZZX106-R 1 pc. (Manifold base) ZX100-K15LZ-EC 5 pcs. (Vacuum single unit) ZX-BM1 1 pc.
Q_Address bit 7 6 5 4 3 2 1 0 1 ID5 ID4 ID3 ID2 ID1 2 (6) Return of the final station number Indicates the range of the ID of the controller (LEC) to communication when the initial is processed. ID number is set in binary digit. Input range is from 1 to 5. If the set value is lower than 0 or larger than 5, 5 is set. ID bit 3 2 1 0 1 0 0 0 1 2 0 0 1 0 3 0 0 1 1 5 0 1 0 1 45 - 13.
1 2 3 4 5 6 7 / byte1 Bit No. 0 1 2 Reserved 3 () 4 () 5 6 7 byte2 Bit No. 0 Reserved : : 7 Reserved byte3 Bit No. 1 0 1 1 2 2 2 3 4 SI 5 Reserved 6 Reserved 7 Reserved 1Bit0 1 ON 2Bit2 3 ON -63No.EX-OMN0029CN-D byte0 Bit No. 0 0 1 1 2 2 3 3 4 4 5 5 6 6 7 7 byte1 Bit No. 0 8 1 9 2 Reserved 3 Reserved 4 Reserved 5 Reserved 6 Reserved 7 Reserved -64No.EX-OMN0029CN-D
Symbol 2 position single 3 position closed center 3 position exhaust center 3 position pressure center 2 position double (Double solenoid) 2(B) (A)4 2(B) (A)4 2(B) (A)4 2(B) (A)4 2(B) (A)4 (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) Manifold Specifications Piping specifications Note 3) Note 4) Note 4) Port size Note 1) 1 station weight (g) 5 stations
3/16" 1/4" 1/8", 5/32" 3/8" 1/2" 5/32" 3/16" 1/4" 5/16" 3/8" Inch size 3/16", 1/4" 1/4" 5/16" ASF Flow rate (l/min (ANR)) 1050 100 130 290 660 1390 420 920 230 460 Controlled flow (Free flow) Effective area (mm 2) 16 1.5 2 4.5 10 21 6.5 14 3.5 7 Note) Flow rate values are measured at 0.5 MPa and 20C.
F 3 COMPRESSED AIR THEORY Units Pressur Prooerties of Gases lsothermic change (Boyle's Law) lsobaric change Charles Law Law of Gay Lussac lsochoric change Adiabatic (lsentropic) change Standard Volume Flow Bernoulli's Equation Air Humidity Relative humidity Pressur and Flow Use of the diagram: Formulae: 6 6 I 1 0 1 0 1 1 1 1 1 1 1 1 1 2 1 2 1 2 1 2 1 2 1 3 1 5 1 6 1 6 AE 36 36 5 AIR TBEATMENT
No. 1 40% 60% 12mm 5mm Step Axis 1 Step No. 1 Posn 12 .00mm Force 40% Step Axis 1 Step No. 1 Posn 5 .00mm Force 40% 60 5 SET SET P.2735 5.3 10 - (5) 2.
55.8 8.5 (6.3) 8 5 22 M5, 1/8 6 36 (27.6) 1 (IN) port M5, 1/8 2 (N.C.) port 1/8, 1/4 1/8, 1/4 2 (N.C.) port 1 (IN) port 2 x M3 x 5 2 x M4 x 6 15 12.8 Bracket assembly part no.
(P) (B) 2 (A) 4 3 position exhaust center (A) 4 (B) 2 5 (R1) 3 (R2) 1 (P) 3 position pressure center (A) 4 (B) 2 i 5 (R1) 1 (P) 3 (R2) 5 (R1) 3 (R2) 1 (P) (This figure shows a closed center type.)
[C] Correction factor 5 to 30 1.41 35 1.21 40 1 45 0.92 50 0.75 55 0.63 60 0.53 Inlet air temp. [C] Correction factor 5 to 45 1.15 50 1.07 55 1 60 0.95 65 0.9 70 0.86 75 0.82 80 0.79 Inlet air temp. [C] Correction factor 5 to 45 1.21 50 1.10 55 1 60 0.87 65 0.76 70 0.74 75 0.72 80 0.70 Inlet air temp. [C] Correction factor 5 to 30 1.3 35 1 40 0.82 45 0.68 50 0.57 Inlet air temp.
NBR seal) 5 to 60C Note 1)/5 to 99C Note 1) (FKM seal) VNH A VNH B 1 3 1 3 Pressure Temperature Lubrication 5 to 50C Note 1) 0.25 to 0.7 MPa Pilot air Not required (Use turbine oil Class 1 ISO VG32, if lubricated.)
Content 0 1 1 1 2 Reserved 3 1 4 1 5 Reserved 6 1 7 1 -67No.EX-OMQ0015CN Unit diagnostic status 0 7 6 5 4 3 2 1 0 Byte 2 Bit No. Content 0 10 1 11 2 12 3 13 4 14 5 15 6 16 7 17 Unit diagnostic status 1 7 6 5 4 3 2 1 0 Byte 3 Bit No.
Inch size 1/8" 1/4" 5/32" 1/8" 5/32" 1/4" 5/16" 1/8" 5/32" 1/4" 5/16" 3/8" 1/4" 5/16" 3/8" 3/8" 1/2" Free flow 0.2 0.3 0.4 0.6 0.6 0.7 1.0 1.3 1.5 1.6 1.7 2.5 4.4 4.8 C values: Sonic conductance Controlled flow 0.2 0.3 0.4 0.7 0.8 0.6 0.9 1.3 2.1 2.4 3.3 4.4 4.9 dm3/(sbar) Free flow 0.3 0.4 0.2 0.3 0.3 0.4 0.4 0.3 0.3 b values: Critical pressure ratio Controlled flow 0.2 0.2 0.3 0.3 0.3
REC 1/8", 5/32", 3/16" 1/4" 3/16", 1/4" 5/16" 1/4", 5/16" 3/8" 1/8", 5/32" 5/32" 3/16" Inch size 7 12 Air flow (l/min (ANR)) 38 Controlled flow CX 0.1 0.2 Effective area (mm2) 0.6 CY 100 180 230 260 390 460 Flow rate (l/min (ANR)) Free flow 1.5 2.7 3.5 4 6 7 Effective area (mm2) MQQ M Note) Supply pressure: 0.5 MPa, Temperature: 20C In-line Type RHC Air Flow/Effective Area MK(2) AS2001FM