-11 CM MC C1 CM ILS MC ILS V V CN CN MC V V CN CN PRS PRS IDFB37E IDFB55E/75E-46 CM GFCI R FM FM16 MC THR MC1 MC1 MC2 CM PE PRS MC2 PRS1 FM PE PRS2 PRR PRR ILS C01 THR W1 TB T TB1 W2 TB2 MC1 PRR C01 CM C1 MC2 PRS1 GFCI P PRS2 THR OLR P EDV PC EDV PE T V IDFB Series 6-4 6-3 IDX-OM-W035 6 6-5 (IDFB55E,75E) (IDFB22E,37E) ,, IDFB Series 6-5 6-4 IDX-OM-W035 7
Brown Brown Load Load Switch 1 Switch 1 Blue Blue Brown Brown Switch 2 Switch 2 Blue Blue Load voltage at ON = Power supply voltage Internal voltage drop x 2 pcs. = 24 V 4 V x 2 pcs. = 16 V Load voltage at OFF = Leakage current x 2 pcs. x Load impedance = 1 mA x 2 pcs. x 3 k = 6 V Example: Power supply is 24 VDC Internal voltage drop in switch is 4 V. Example: Load impedance is 3 k.
, D-F9P(V), D-F9B(V) Auto Switch Specifications Grommet D-F9, D-F9V (with indicator light) D-F9N Perpendicular D-F9BV D-F9NV D-F9P Perpendicular D-F9B Perpendicular D-F9PV Auto switch part no.
, D-F9P(V), D-F9B(V) Auto Switch Specifications Grommet D-F9, D-F9V (with indicator light) D-F9N Perpendicular D-F9BV D-F9NV D-F9P Perpendicular D-F9B Perpendicular D-F9PV Auto switch part no.
(N) and (P+) (N-)) of the main circuit converter is displayed. 0900 V 62 - 6.
V Ps + 0.1 293 S = 12.1 log10 () (6) t P + 0.1 T S : Effective area [mm2] V : Air tank capacity [dm3] t : Discharging time [s] Ps : Pressure inside air tank before discharging [MPa] P : Residual pressure inside air tank after discharging [MPa] T : Temperature inside air tank before discharging [K] Pressure switch Power supply Thermometer Solenoid valve Equipment for test Control circuit
Symbol (B) 2 (A) 4 1 (P) 3 (R) Flow Rate Characteristics C [dm3/(sbar)] b Cv C [dm3/(sbar)] b Cv 14/2(PA/B) 4/25/3(A/BEA/EB) Flow rate characteristics Valve model Port size Body ported 10-VQD1121(V)-L M-M5 10-VQD1121 -L M-M5 10-VQD1151(V)-L M-M5 10-VQD1151W-L M-M5 0.05 0.07 0.06 0.07 Base mounted (With sub-plate) 0.22 0.27 0.22 0.27 0.16 0.24 0.10 0.25 0.05 0.07 0.05 0.07 0.19 0.28 0.22 0.27
ALARM is expressed as negative-logic circuit. (2) Positioning Operation (4) Stop by the STOP Signal 24 V 0 V 24 V 0 V Power supply Power supply ON OFF ON OFF IN0-3 IN0-3 Input Input ON OFF OUT0-3 STOP Output ON OFF BUSY OUT0-3 Release Hold BUSY External lock Output ALARM 0 mm/s Speed Positioning operation Release Hold External lock OUT0-3 output signals are ON in the same state as the input
Normally closed Normally open Double acting VNA01 VNA02 VNA03 Coil rated voltage (V) AC (50/60 Hz) 100 V, 200 V, Other voltage (Option) 24 V, Other voltage (Option) 15% to +10% of rated voltage 35C or less (When rated voltage is applied.) 5.6 VA (50 Hz), 5.0 VA (60 Hz) 12 VA (50 Hz), 10.5 VA (60 Hz) 3.4 VA (50 Hz), 2.3 VA (60 Hz) 7.5 VA (50 Hz), 6 VA (60 Hz) DC 12 (P1) 12 (P1) 10 (P2) Allowable
Applicable for strong alkali-based cleaning fluid Suitable for filtering cutting fluids P.57 P.57 P.58 (For coarse filtration) (For coarse filtration) Leg Material: Stainless Steel X47 P.58 54 FGF Series Made to Order Please consult with SMC for details.
PA IN PAX Solenoid coil PB Coil: Class B, Class H Rated voltage Model AC Standard Option 100 V, 200 V 48 V, 110 V, 220 V, 240 V Orifice size (mm) Model Port size 10 VXD2130 Rc 1 4, 3 8, 1 2 Rc 3 8, 1 2 Rc 3 4 DC 24 V 12 V 15 20 VXD214 VXD215 VXD226 VXD227 VXD238 VXD239 2 0 Standard Option 2 0 2 0 Rc 1 25 Material 2 0 32A 35 40A 40 2 0 Body Seal Brass/BC6, Stainless steel NBR, EPDM, FKM
Size 100 125 150 R V Voltage Symbol Voltage 30 3-phase AC200V(50Hz) AC200/220V(60Hz) Option 1 Ventilation direction Option None(Ventilated from back) Ventilated from the right Ventilated from the left Anti-corrosive treatment Option None Symbol Symbol NIL NIL C 1 K 2 P 3 R V Timer type solenoid valve with auto drain Ground fault circuit interrupter Ventilated from the top For medium air pressure
Caution Operation instructions Consult P/A when using solvents other than water.
L1 L2+A5 L3 2 1 W V 2 E= ( ) 2 9.8 1000 Collision speed V=1.4 Va *) Corrected coeficient 1 10 420 E= ( ) =0.09 2 9.8 1000 V=1.4 x 300=420 Calculate kinetic energy E(J) of moment. Calculate allwable kinetic energy Ea(J). Check that kinetic energy of moment does not exceed allowable kinetic energy.
Maximum current rating Voltage without load (V peak) 5.0 0 to 20 [V] 100 Peak voltage Over 20 [V] up to 30 [V] (2) Circuit (of class 2) which is of maximum 30 Vrms (42.4 V peak) or less, with UL 1310 class 2 power supply unit or UL 1585 class 2 transformer. Grounding Warning 1. Make sure the product is grounded to ensure the noise tolerance of the controller.
P 17 P T 21.5 27.5 A I R R G Y 7 R A I 8 17.5 32 8 42 Side A Side B Scale: 40% 12 Rotary Gripper Series MRHQ Construction Description Material Note Parts list No.
THR TDR PRS2 P CN PE EDV FOR OPTION V 11-6Electric wiring diagram 11 4 IDFB Series IDX-OM-W034 Air Dryer 12 Specification for Option V 12 Specification for Option V This product mounts the timer operated auto drain in Item 2 Specifications.