The VFM offers an internal or external pilot body option and a variety of actuator choices.Fluid: air, inert gas, Operating pressure range: 15 to 150 PSIG, Effective area (Cv): 18mm 2 (1.0), Maximum frequency (mechanical operation style): 300 c.p.m. or less, Weight: 10.3 oz., VALVE, MECH L (NYLON), VALVE, VM BODY PT 1/4, .70400 lb

The VFM offers an internal or external pilot body option and a variety of actuator choices.Fluid: air, inert gas, Operating pressure range: 15 to 150 PSIG, Effective area (Cv): 18mm 2 (1.0), Maximum frequency (mechanical operation style): 300 c.p.m. or less, Weight: 10.3 oz., VALVE, MECH L (TOGGLE), VALVE, VM BODY PT 1/4, .89126 lb

The VFM offers an internal or external pilot body option and a variety of actuator choices.Fluid: air, inert gas, Operating pressure range: 15 to 150 PSIG, Effective area (Cv): 18mm 2 (1.0), Maximum frequency (mechanical operation style): 300 c.p.m. or less, Weight: 10.3 oz., VALVE, MECH L (NYLON), VALVE, VM BODY PT 1/4, .68200 lb

Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: B2 [TSJ1/4 (Compression Fitting)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: None, Operation Manual: K

Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A3 (Bracket C), Operation

Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: E (Panel Mount Adapter), Operation

Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: F (Panel Mount Adapter + Front

Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: None, Operation Manual: Y

Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: None, Operation Manual: Y (w/o Operation

Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A3 (Bracket C), Operation

Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: E (Panel Mount Adapter), Operation

Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: F (Panel Mount Adapter + Front

Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: None, Operation Manual: Y

Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: None, Operation Manual: Y (w/o Operation

Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: w/o Lead Wire, Bracket: A3 (Bracket C)

Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: w/o Lead Wire, Bracket: A3 (Bracket C)

Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate)

Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: C01 (Rc1/8), Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A), Operation Manual: K (Operation Manual, Calibration Certificate)