SMC Corporation of America
Elite Part Number Search
Search Results "CQ2B40TN-25DZ-XB7"

Mounting: Through-hole, Standard, Bore Size: 40mm, Port Thread: NPT; 32 to 100 Bore, Stroke: 45mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces, Temperature Resistant Option: XB6 [Heat Resistant (-10 to 150°C)]

Magnet: None, Mounting: B [Through Hole (Standard)], Type: Standard, Bore Size: 40mm, Port Thread Type: NPT 32-100 Bore, Stroke: 40mm, Body Option: Rod End Male Thread, Auto Switch Groove: Auto Switch Mounting Grooves, Mounting Bolt: None, Rod End Bracket: Double Knuckle Joint, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Mounting Threads: -, Rod Type: -, Speed Control Type

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Mounting: B (Through-hole, Standard), Bore Size: 40mm, Port Thread: TN (NPT; 32 to 100 Bore), Stroke: 5mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces), Temperature Resistant Option: XB6 [Heat Resistant (-10 to 150°C)]

Magnet: None, Mounting: Through-hole, Standard, Type: Pneumatic, Bore Size: 40mm, Port Thread: NPT; 32 to 100 Bore, Stroke 1: 40mm, +: +, Stroke 2: 75mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None

This is a legacy product. Please contact us for the latest version.sales@ocaire.com CQ2-Z COMPACT CYLINDER. CYLINDER. ACTUATOR. 40MM CQ2-Z OTHERS (COMBO). 1.433 lb. MC.

SMC has redesigned the NCQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions.  Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, single rod, large bore , Bore size (mm): 125, 

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, double rod, large bore, Bore size *: 125, 140, 160

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, double rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,

SMC has redesigned the NCQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions.  Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, double rod, large bore, Bore size (mm): 125, 

SMC has redesigned the NCQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions.  Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, single rod, large bore , Bore size (mm): 125, 

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, BASE CYLINDER, ACTUATOR, NCQ2-Z COMPACT CYLINDER, LC, 32MM NCQ2-Z OTHERS (COMBO), .53213 lb, SeriesModelActionNoteCQ2StandardCQ2Double acting, Single rodExcept with rubber bumper

SMC has redesigned the NCQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions.  Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, single rod, large bore , Bore size (mm): 125, 

Cylinder (Tube) Inner Diameter(φ): 5", Stroke(mm): 6", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: -, Environment, Applications: Standard, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches: N/A, Type of Auto Switch Mounting: N/A, Custom-made Specifications

Cylinder (Tube) Inner Diameter(φ): 3/8", Stroke(mm): 1/2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~0.7, Support bracket: Basic, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 3/8", Stroke(mm): 1", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~0.7, Support bracket: Basic, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 5/8", Stroke(mm): 1", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~0.7, Support bracket: Basic, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 5/8", Stroke(mm): 4", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~0.7, Support bracket: Basic, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 5/8", Stroke(mm): 5", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~0.7, Support bracket: Basic, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches