Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Overall Length: Standard, Bore Size: 075 (3/4"), Stroke: 150 (1 1/2"), Body Option: C (Rubber Bumper)
Magnet: D (Built-in), Mounting: C (Rear Clevis), Overall Length: Z (Super Compact), Bore Size: 200 (2"), Stroke: 150 (1 1/2"), Body Option: C (Rubber Bumper)
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
Bore Size: 25mm, Symmetric Type: Standard, Stroke: 150mm, Adjuster: C (Both Side Adjusters/Metal Stoppers), Function: Standard, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)
Series: LEY, Size: 25, Motor Mounting Position: Top Side Parallel, Motor Type: G (High Performance Battery-less Absolute, Step Motor, 24 VDC), Lead: C (Size 16: 2.5mm, Size 25: 3mm, Size 40: 4mm), Stroke: 150mm, Motor Option: C (w/Motor Cover), Rod End Thread: Rod End, Female Thread, Mounting: Ends Tapped/Body Bottom Tapped, Parallel, In-line), Actuator Cable Type, Length: R5 (5m), Controller
Size: 16, Motor Mounting Position: Top Mounting, Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 150mm, Motor Option: C (w/Motor Cover), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped/Body Bottom Tapped, Top Mounting & In-line, Actuator Cable Type, Length: R3 (3m), Controller: C91 (Ether Net/IPâ„¢), Mounting: 8 (DIN Rail)
Series: LEY, Size: 40, Motor Mounting Position: Top Side Parallel, Motor Type: G (High Performance Battery-less Absolute, Step Motor, 24 VDC), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 40: 16mm), Stroke: 150mm, Motor Option: C (w/Motor Cover), Rod End Thread: Rod End, Female Thread, Mounting: Ends Tapped/Body Bottom Tapped, Parallel, In-line), Actuator Cable Type, Length: R3 (3m), Controller
Size: 16, Bearing Type: L ( Ball Bushing Bearing), Motor Mounting: D (In-line Type), Motor Type: Step Motor (Servo/24VDC), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 150mm, Motor Option: C (with Motor Cover), Guide Option: w/o Guide, Actuator Cable Type: R (Robotic Cable - Flexible cable), Actuator Cable Length: 3 (3m), Controller Type for (LEC, JXC): C91 (JXC91, EtherNet
Size: 16, Bearing Type: L (Ball Bushing Bearing), Motor Mounting Position: D3 (In-line; Motor Cover Direction: Top), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 150mm, Motor Option: C (w/Motor Cover), Guide Option: w/o Option, Actuator Cable Type, Length: R3 (3m), Controller: C91 (Ether Net/IPâ„¢), Mounting: 8 (DIN Rail)
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~70, Operating Pressure(MPa): 0.05~1, Cushion: Air cushions on both sides + with damper cushions, Specification: Without
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~70, Operating Pressure(MPa): 0.05~1, Cushion: Air cushions on both sides + with damper cushions, Specification: Built-in
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~70, Operating Pressure(MPa): 0.05~1, Cushion: Air cushions on both sides + with damper cushions, Specification: Built-in
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~70, Operating Pressure(MPa): 0.05~1, Cushion: Air cushions on both sides + with damper cushions, Specification: Without
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Support bracket: None, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: None, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: None, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: None, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: None, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: None, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: M9B, Lead Wire Length(m): 3, The number of the switches: 2, Type of Auto