, Grommet terminal, Conduit terminal, DIN terminal 1 (P) 3 (R) Note 1) Use dry-air at low temperature.
Note 6) Ground fault circuit interrupter is not mounted in product other than option "R". 6 1 6.
Normal output Reversed output P_1 = A-(A-B)/4 n_1 = B+(A-B)/4 A = Max. pressure H_1 = (A-B)/2 H_1 = (A-B)/2 B = Min. pressure The set values of OUT2 become as follows "_", i.e. "P_2", "n_2" and "H_2".
T XA H VA VB 3 U X PW 6 Section XX details XAH9 depth 6 S Q GC GA GB 2 x P PB XAH9 depth 6 2 x P (Plug) G J K b a PA + Stroke E FB FA e c d A + Stroke B + Stroke C + Stroke T-slot dimensions [mm] [mm] Bore size [mm] a b c d e Bore size [mm] f f 12 3.3 5.8 2.6 1.6 4.8 16 3.7 6.2 3 2.5 6.5 20 5.4 8.4 4.5 2.8 7.8 25 5.4 8.4 4.5 3 8.2 12 7 16 2.5 20 8.5 25 6 50 mm stroke or less Top-ported type
T0604 How to Order Max. operating pressure Max. operating pressure T 0604 B 20 Length per roll Color Nylon tubing 20 20 m 100 m roll (Black, white only) Operating temperature (C) Symbol Color B W R BU Y G Black White Red Blue Yellow Green Maximum operating pressure is 1/3 max. of burst pressure at 60C, considering the safety ratio. Tube size 100 O.D. 6 I.D. 4 14-13-10
A B PF3W504 0 4 PF3W520 0 16 PF3W540 0 40 PF3W511 0 100 Display A Set A and B to the values shown in the table on the left.
8370: JIS B 8361: JIS B 9960-1: -1 ) JIS B 8433-1993: *2) 1. 2. 3. 1. 2. 3. 4
A-phase pulse B-phase pulse 11 12 11 10 10 Count multiplier In rod extending direction, A-phase turns on first, then B-phase turns on with the delay of In rod retracting direction, B-phase turns on first, then A-phase turns on with the delay of approximately 90 phase difference. approximately 90 phase difference. Counter performs addition in and does subtraction in .
Basic inertia moment 2 r m I = m : Weight of load (kg) r : Load center of gravity and distance of rotation axis. (m) r m Fig.9 Inertia moment This shows inertia moment of m (weight) at r from the rotation axis. Calculation of inertia moment depends on the shape of the object.
Note) Depths of mark Q1, Q2 indicate that the body(A)/(B) are penetrated respectively.
P A B C D G J M N Q R S T U V B AM50 3/41 90 237.7 32 45 30 45 70 66 40.5 11 13 113 3.2 52.5 259.2 AM60 1 90 314.8 32 45 30 45 70 66 40.5 11 13 113 3.2 52.5 336.3 Semi-standard specifications SUS bowl Model No.
AMX-OMZ0094 PRODUCT NAME Micro Mist Separator MODEL / Series / Product Number AMD50-(F,N)06 ~ (F,N)10(B,C,D)(-J,L,R,W,Z)-D AMD60-(F,N)10(B,C,D)(-J,L,R,W,Z)-D Contents Page 1. Safety Instructions 2 to 6 2. Application 7 3. Standard specifications 7 4. How to Order 8 5. Construction / Options / Replacement parts 9 6. Bowl assembly specifications 10 to 11 6-1.
Flow Rate Characteristics Relief Characteristics Pressure Characteristics Testing methods conform to JIS B 8372.
JIS B 8370: General rules for pneumatic equipment. JIS B 8361: General rules for hydraulic equipment. JIS B 9960-1: Safety of machinery Electrical equipment of machines. (Part 1: General requirements) JIS B 8433-1993: Manipulating industrial robots Safety. etc. 2) Labor Safety and Sanitation Law, etc. Caution: Operator error could result in injury or equipment damage.
Product weight [kg] Model Stroke Additional weight with lock Size 50 75 100 150 8 1.06 1.23 0.16 16 1.87 2.26 0.32 25 3.50 4.10 4.90 0.61 -5- 1.3 Construction LESYH*R / LESYH*L R type as shown L type opposite as shown Case of D type Component parts No. Description Material Remarks No.
Then the pressure in the pressure action chamber B falls to open the main valve C. < Valve closed > When the coil o is not energized, the pilot valve A is closed and the pressure in the pressure action chamber B rises and the main valve C closes.
IS*-OMX0095-B PRODUCT NAME Pressure Switch Pressure Switch with T-Spacer Pressure Switch with L-Piping Adapter Pressure Switch with Piping Adapter MODEL / Series / Product Number IS10M-(20,30,40,50,60)(-1,6,L,P,Z)-D IS10T-(20,30,40,50,60)-(F,N)(-6,L,P,Z)-D IS10L-(20,30,40,50,60)-(F,N)(-6,L,P,R,Z)-D IS10E-(20,30,40,50,60)-(F,N)(-6,L,P,R,Z)-D Contents Page 1. Safety Instructions 2-7 2.
(A)(B) (A)(B) Rc 1/8 4 2 4 2 (kg) 0.83 5 1 3 5 1 3 (mm2) PA 44 38 32 (EA)(P)(EB) (EA)(P)(EB) (A)(B) (A)(B) P1=0.7MPa,P2=0.5MPaS PB 38 40 31 4 2 4 2 (mm2) AEA 90 5 1 3 5 1 3 P2=0.5MPaS BEB 77 (EA)(P)(EB) (EA)(P)(EB) ()( ) 2.8N m 7 VFR3000-OMY0001 VFRA3000,4000 3 VFRA3000 VFRA4000 3 1(P) 8 VFR3000-OMY0001 R , 9 VFR3000-OMY0001 No. 1ISO VG 32 R (1) (2) (3) (4) (5) (6) 10 VFR3000
dimensions XAH7 depth XL 4-YY depth YL XB XAH7 a b X0.02 c d e XAH7 XC XL X Section XX detail Bore size (mm) a b c d e 40 6.5 4 11 5.5 10.5 WB Z WA Section XX 8.5 50 4.5 13.5 7.5 13.5 11 7 18.5 63 10 17.8 Bottom view L 4-OA through 4-OB counter bore depth OL Section XX WA Z Section XX IA 4-NN through IC 4-MM depth ML R X0.02 HA T-slot for hexagon bolt X0.02 DA DB mIB ID X U VB VA H T PW
High Suction Vacuum Work 1 Work 2 Work n Max.A ON point OFF point Min.B Not adsorption Work 1 Work 2 Work n Atmosphere A B 4 A B 4 = A ON point Max.A: Maximum pressure value when work piece is vacuumed. Min.B : Maximum pressure value when work piece is not vacuumed.