Port size Symbol Port size Model PSE570 PSE573 PSE574 PSE575 PSE576 PSE577 01 R1/8 (with M5 female thread) 02 R1/4 (with M5 female thread) For pressure switch precautions and specic product precautions, refer to the Operation Manual on the SMC website.

Port size With One-touch fitting 01 M5 M5 R 1/8 R 1/4 R 3/8 R 1/2 02 03 04 Needle Valve/Flow Rate Characteristics Note) The flow rate characteristics are representative values.

Series AS-FG How to Order AS 1 0 3 2 F G 01 06 Body size M5 standard 1/8, 1/4 standard 3/8 standard 1/2 standard 1 2 3 4 Option Type Nil S None With seal 2 3 Elbow Universal M5 and U10/32 are not available with seal. Control type Applicable tubing O.D.

(mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in4M5 x 0.8AS1201FG-M5-04AS1211FG-M5-04AS1301FG-M5-04AS1311FG-M5-04

(mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in6M5 x 0.8AS1201FG-M5-06AS1211FG-M5-06AS1301FG-M5-06AS1311FG-M5-06

Please contact us for the latest version.sales@ocaire.com, SPEED CONTROL W/FITTING, AIRLINE EQUIPMENT, FLOW CONTROL W/FITTING, A5, AS***F M5 CLEAN-ROOM, 1.79968 lb, Applicable tubing O.D. (mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in3.2M5 x 0.8AS1201FG-M5-23AS1211FG-M5-23AS1301FG-M5-23AS1311FG-M5-23

PAX1000, PA3000, PA5000 Proper tightening torque Nm Connection threads 12 to 14 Rc 1/4 22 to 24 Rc 3/8 28 to 30 Rc 1/2 28 to 30 Rc 3/4 PB1000 Proper tightening torque Nm Connection threads 1/6 turn after tightening by hand M5 2 to 3 Rc 1/8 Since the threaded sections of the PB1000 are resin, take particular care not to tighten any more than necessary.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 84 100 M12 x 1 Cable connection threads 12.5 (11) SMC REGULATOR ITV2000 M5 x 0.8 Solenoid valve EXH 93 Rc1/4 Exhaust port Solenoid valve EXH OUT 19 13.5 EXH (3) SUP (1) OUT (2) 12 Flat bracket P3020114 (Optional) 36 2 x Rc1/4, 3/8 Port size 4 x M5 x 0.8

-X465 0.1 to 1 Set pressure range (MPa) Desolution of setting and display (MPa) Power supply voltage Specifications AU 0.001 Class 10 With M5 fitting (Applicable tubing O.D. 6) Pressure switch Cleanliness Breather port 12 to 24 VDC 10%, Ripple (p-p) 10% or less (With reverse connection protection) 45 mA or less (but 70 mA or less at current output) AF IR1000/2000: With M5 fitting (Applicable

PB1000 PA Proper tightening torque (Nm) Connection threads M5 1/6 turn after tightening by hand PAX Rc 1/8 2 to 3 4. Do not drop or bump. Do not drop, bump or apply excessive impact (1000 m/s2) when handling. 5. Never mount in a place which will be used as a scaffold during piping work. Damage can be caused if subjected to an excessive load.

8 1/4, 3/8 VCL31 104 24 25 59 46 57 60 54.5 48.5 101 57 68 30 50 84 36.5 13.5 15 32 25 23 M5 8 1/2 107 26 26.5 64.5 48 62.5 62 60 50.5 103 62.5 70 22 45 89 41 11 17 36 22.5 23 M5 8 1/4, 3/8 VCL41 111.5 26 26.5 66.5 48 64.5 62 62 50.5 103 64.5 70 30 50 93.5 41 13.5 17 36 25 23 M5 8 1/2 119 26 26.5 70 48 68 62 65.5 50.5 103 68 70 35 60 101 41 17.5 17 36 30 28.2 M5 8 3/4 Note) For class H

71 68 104 1/2 22 45 90 41 11 17 36 22.5 23 M5 8 26 84 48 74.5 103 74.5 70 107 1/4, 3/8 VCS41 30 50 94 41 13.5 17 36 25 23 M5 8 26 88 48 78.5 103 78.5 70 111.5 1/2 35 60 102 41 17.5 17 36 30 28.2 M5 8 26 96 48 86.5 103 86.5 70 119 3/4 4 Direct Operated 2 Port for Steam Series VCS How to Order Manifolds How to Order Manifold Assemblies (Example) D VV2C S 2 02 01 Enter the valve and option

Caution Caution When the VEX3420 air operated power valve is delivered from our factory, the M5 threaded pilot ports P1 and P2 in the cover are open and the Rc1/8 pilot port in the subplate is plugged. Before connecting pipes to P1 and P2 ports in the subplate, remove the 1/8 plug from the subplate and put M5 plugs into P1 and P2 ports in the cover.

Rz 12.5 45 Female thread size Chamfered dimension D (Recommended value) M5 5.1 to 5.4 10-32UNF 5.0 to 5.3 2. Use G external threads with G internal threads. D For Uni Thread 45 Tightening method 1.

Screw lightly the auto switch mounting screw (M5 x 0.8 x 16 L). 4. Set the whole body to the detecting position by sliding, tighten the mounting screw (M5 x 0.8 x 16 L) to secure the auto switch. (The tightening torque should be about 2 to 3 Nm.) 5. Modification of the detecting position should be made in the state of 3. Auto Switch Mounting Bracket Part No.

33.5 7 5.5 5.5 5 M14 x 1.5 M10 x 1.25 M10 x 1.25 M8 x 1.25 26.5 22 20 20 51 42.5 34.5 30 181 159 146 146 M26 x 1.5 M26 x 1.5 M20 x 1.5 247 217 204 200 1/8 40 32 25 20 24 22 22 18 26-0.033 0 1/4 1/8 1/8 16 13 13 26-0.033 0 32-0.039 0 8 10 M32 x 2 1011Axial foot (L): RECL G H G F Width across flats B2 A K 2 x P (Rc, NPT, G) NA AL F Width across flats B1 H1 2 x NN Standard port Relief port M5

female thread M5 x 0.8 OUT IN OUT Thread type Nil N Rc NPT OUT IN OUT Note 1) Use caution not to tighten excessively when mountinga pressure gauge, otherwise it may result in a breakdown.

Body fixed A Maintenance Warning L Model Screw size Max. tightening torque [Nm] A [mm] L [mm] LEFl16 M3 0.6 3.5 20 LEFl25 M4 1.5 4.5 24 LEFl32 M5 3.0 5.5 30 LEFl40 M6 5.2 6.6 31 Maintenance frequency Perform maintenance according to the table below.

Applicable Model Model AR10 Port size M5 AR 10 X406 M5 A 0.4 MPa setting w q Option/Semi-standard: Select one each for a to f. Option/Semi-standard symbol: When more than one specification is required, indicate in alphabetic order.