Add -61 at th end of the part number for the flexible lead wire except D-Y59, D-Y69, DY7 and D-M9/M9V type auto switches. L D-A73 (Example) RS H A Lead wire length RZQ 5 m None Nil L 0.5 m 3 m Z N MI W S Applicable for the connector type (D-C) only.

Add -61 at th end of the part number for the flexible lead wire except D-Y59, D-Y69, DY7 and D-M9/M9V type auto switches. L D-A73 (Example) CLQ Lead wire length MLGP 5 m None Nil L 0.5 m 3 m Z N RLQ Applicable for the connector type (D-C) only.

Applicable Auto Switch Model Reed Switch Solid State Switch D-C7/C8 D-C73C/C80C D-B5/B6 D-B59W D-A3/A4 D-A3lA/A44A D-A3lC/A44C D-A7/A8 D-A7lH/A80H D-A73C/A80C D-A79W D-A5/A6 D-A59W D-A9/A9lV D-9/9lA D-E7lA/E80A D-Z7/Z8 D-H7 D-H7C D-H7BAL D-H7lF D-H7lW D-G5/K5 D-G5BAL D-G59F D-G5NTL D-G5lW/K59W D-G39/K39 D-G39A/K39A D-F7/J7 D-J79C D-F7lF D-F7BAL D-F7lV D-F7NTL D-F7lW(V) D-F5/J5 D-F5BAL D-F5lW

type D-Z7 type Note 1) Note 1) D-Z8 type D-A9 type D-F9 type D-Y6 type D-Y7 type Note 1) Vertical outlet types cannot be mounted.

Add -61 at th end of the part number for the flexible lead wire except D-Y59, D-Y69, DY7 and D-M9/M9V type auto switches. L D-A73 (Example) CS1 Lead wire length C76 5 m None Nil L 0.5 m 3 m Z N C85 Applicable for the connector type (D-C) only.

Without bracket (Bottom view) Bracket thickness is approx. 1.6mm Model Piping port size A B C D E F G H I J K L LFE13(Z) 3/8 90 73 40 23.5 56 83 89 24 6 1.6 96 87 LFE14(Z) 1/2 104 73 40 23.5 56 83 89 28 6 1.6 96 87 LFE26(Z) 3/4 105 78 50 29 67 94 100 35 6 1.6 115 106 LFE38(Z) 1 120 90 55 32 73 100 106 41 6 1.6 115 106 Model M N O P Q R S T U Bracket weight LFE13(Z) 48 39 4.6 12 11.5 52 28

Mounting correctly Mounting incorrectly Solid state D-G59, D-G5P, D-K59, D-G5BA D-G59W, D-G5PW, D-K59W D-G59F, D-G5NT, D-G5NB Solid state D-H7A1, D-H7A2, D-H7B, D-H7BA D-H7C, D-H7NF, D-H7NW, D-H7PW, D-H7BW Reed D-C73, D-C76, D-C80, D-C73C, D-C80C Reed D-B53, D-B54, D-B64, D-B59W Auto switch Auto switch Auto switch mounting screw M3 x 0.5

mounting type Applicable auto switch: D-A79W D-A7 D-A80 D-A7H D-A80H D-A73C D-A80C D-F7WV D-F7BAL D-F7BAVL D-F7W D-J79W D-F7NTL D-F79F D-F7V D-J79C D-F7 D-J79 [For CLKQ] [For CKQ] B A B A U U Direct mounting type Applicable auto switch: D-A9 D-A9V D-F9WV D-F9BAL D-M9V D-F9W [For CKQ] D-A9, D-F9W D-A9V, D-M9V D-F9WV D-F9BA U U B A [For CLKQ] D-A9, D-F9W D-A9V, D-M9V

Z (example) C73CZ 3m . L (example) C73CL None . N (example) C73CN Notes) Solid state switches marked "" are produced upon receipt of order. You do not need to specify "N" (i.e., without lead wire) for D-A3, D-A44, D-G39, and D-K39.

Hs A B A B Auto switch mounting height (mm) Proper auto switch mounting positions (mm) D-J79W D-F7BAL D-F7F D-F7NTL D-A7H D-A80H D-F7 D-J79 D-F7W D-F79W D-F7BA D-F7W D-F7F D-J79W D-F7WV D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7V/J79C D-A73C D-A80C D-F7V D-F7WV D-J79C D-A79W D-A7 D-A80 Bore size (mm) D-A7/A80 D-A79W Bore size (mm) Hs Hs Hs Hs Hs Hs 20 B A B A B A A B 25 20 32 34 35 38 32.5 38.5

Note 12 16 20 25 32 40 50 D-F7 , J79 D-F7 V D-J79C D-F7 W, J79W D-F7 WV D-F7BAL, F7BAVL D-F79F D-F7NTL D-F7, D-F7V D-J79, D-J79C D-F7W, D-F7WV D-J79W D-F7BAL, D-F7BAVL D-F7NTL, D-F79F -X Switch mounting screw (M3 x 0.5 x 10 ) Switch spacer Switch mounting nut D-A7 , A80 D-A73C, A80C D-A7 H, A80H D-A79W 6 6 6 32, 40 50 BQ-2 20Data D-F9W, D-F9WV D-F9BAL 5.5 3 4 5 5.5 5.5 5.5 Switch mounting

Minimum Strokes for Auto Switch Mounting Hydraulic Fluid Compatibility (mm) Hydraulic fluid Compatibility D-A7 D-A80 D-A73C D-A80C D-A7H D-A80H D-A9 D-A9V Standard mineral hydraulic fluid Compatible D-F9BAL D-F7WV D-F9W D-F9WV D-F7W D-J79W D-F7BAVL W/O hydraulic fluids Compatible D-F7V D-J79C D-F9 D-F9V D-F7BAL D-F7NTL D-F79F D-F7 D-J79 D-F7LF D-A79W No. of auto switches O/W hydraulic fluids

Hs A B A B Auto switch mounting height (mm) Proper auto switch mounting positions (mm) D-J79W D-F7BAL D-F7F D-F7NTL D-A7H D-A80H D-F7 D-J79 D-F7W D-F79W D-F7BA D-F7W D-F7F D-J79W D-F7WV D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7V/J79C D-A73C D-A80C D-F7V D-F7WV D-J79C D-A79W D-A7 D-A80 Bore size (mm) D-A7/A80 D-A79W Bore size (mm) Hs Hs Hs Hs Hs Hs 20 B A B A B A A B 25 20 32 34 35 38 32.5 38.5

Hs A B A B Proper auto switch mounting positions mm Auto switch mounting height mm D-J79W D-F7BAL D-F7F D-F7NTL D-A7H D-A80H D-F7 D-J79 D-F7W D-F79W D-F7BA D-F7W D-F7F D-J79W D-F7WV D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7V/J79C D-A73C D-A80C D-F7V D-A7 D-A80 D-F7WV D-J79C D-A79W Bore size (mm) D-A79W D-A7/A80 Bore size (mm) Hs Hs Hs Hs Hs Hs 20 A B A B A B A B 25 20 32 31.5 32.5 38.5 35 38 34

Part number of auto switch mounting bracket D-M9 Applicable auto switches D-M9W D-A9 Bore(mm) 12 to 63 Surface with auto switch mounting slot Auto switch mounting surfaces Mounting of auto switch Tightening torque Auto switch Mounting Screw (Nm) Auto switch model Tightening torque D-M9 D-M9W 0.05 to 0.15 D-A9 0.10 to 0.20 NoteAuto switch mounting brackets and auto switches are enclosed with

Minimum Strokes for Auto Switch Mounting Hydraulic Fluid Compatibility (mm) D-A7 D-A80 D-A73C D-A80C D-A7H D-A80H D-A9 D-A9V Hydraulic fluid Compatibility D-F9W D-F9WV D-F7W D-F7WV D-J79W D-F9BAL D-F7BAVL D-F7V D-J79C D-F9 D-F9V Standard mineral hydraulic fluid Compatible No. of auto switches W/O hydraulic fluid Compatible D-F7BAL D-F7NTL D-F79F D-F7 D-J79 D-F7LF D-A79W O/W hydraulic fluid

, Z8 D-Y5, Y6, Y7 D-Y7W, D-Y7BAL 180, 200 2 pcs.