200 300 0 100 200 300 0 100 200 300 0 Detection distance (m) Detection distance (m) Detection distance (m) Example 1) When requiring 300m detection, select the detection nozzle of 1.0 with supply pressure 0.2MPa.

Manifold base Individual port Rc Applicable valve Base weight (g) VVXA311-stations VVXA312-stations VVXA321-stations VVXA322-stations Construction/ Principal Parts Material 1/8 1/4 1/8 1/4 VXA31 5-00 n x 100 + 50 VXA32 5-00 n x 160 + 70 Model/Valve Specifications Av x 10 -6 (m 2) Cv converted C [dm 3/(sbar)] b Cv Oil Air Flow characteristics Max. operating pressure differential (MPa) Orifice

B B B p AW3001 220.5 213.5 219.5 240.5 AW4001 272 265 271 292 IN-OUT reversal mounting "'" DimenSions except B are same as the standard type.

Flow Rate Characteristics Operating Frequency Port size Valve flow rate characteristics 70 Ambient and fluid temperatures (Upper limit) [C] 1, 5, 3 (P , EA, EB) 4, 2 (A, B) 1 R 4/2 (P R A/B) 4/2 R 5/3 (A/B R E) Model 60 C [dm3/(sbar)] b C [dm3/(sbar)] b DXT1215 1/8 1/8 1.3 0.37 1.3 0.23 50 Calculation of effective area S and sonic conductance C: S = 5.0 x C 40 30 20 10 0 0 200 Operating

[mm] 40 170190 41(41.5) 41.5 80190 31.5(32) 32 ( ) : D-A72A7HA80H 25 7. 7. 7. 7. 7.1 7.2 (7.1)A A ON A B A OFFB ON (7.2)A A ON A B A OFFB ON 26 8. 8. 8. 8. 8-1

data: Lights up 2 COM B is having no data to receive: Goes off Note: A secure earth connection (Protection class 3) should be performed for FG terminal.

COM A COM A is receiving data: Lights up COM A is having no data to receive: Goes off COM B COM B is receiving data: Lights up COM B is having no data to receive: Goes off A. For dual power supply use B.

A B C E Applicable clip Clip for P7 Clip for P10 Conforms to JIS B 2401 dimensional standard for O-rings for industrial applications.

200 300 400 500 1000 1500 100 200 300 400 500 1000 1500 100 200 300 400 500 1000 1500 100 200 300 400500 1000 1500 Piston speed mm/s Piston speed mm/s Piston speed mm/s Piston speed mm/s Features 6

VMG1-06-150-300 VMG1-06-200-300 VMG1-06-150-600 VMG1-06-200-600 VMG1-06-150-100 VMG1-06-200-100 VMG1-06-150-150 VMG1-06-200-150 VMG1-08-250-100 VMG1-08-300-100 VMG1-08-350-100 VMG1-08-250-150 VMG1-08-300-150 VMG1-08-350-150 VMG1-08-250-300 VMG1-08-300-300 VMG1-08-350-300 VMG1-08-250-600 VMG1-08-300-600 VMG1-08-350-600 Nozzle size Nozzle length 1.5 2 1.5 2 1.5 2 1.5 2 2.5 3 3.5 2.5 3 3.5 2.5

Auto Switch Proper Mounting Position (Detection at Stroke End) D-A93 12 16 to 25 A B W A B W D-M9B/M9N 12 16 to 25 A B W A B W B D-A93 B D-M9B/M9N/M9P Bore size (mm) A 11.5 W 4 A 15.5 W 5.5 12 16 20 25 0.5 4.5 12 0 4.5 16 4 6 16 3.5 1 20 7.5 2.5 17 5.5 -1 21 9.5 0.5 Specific Product Precautions Be sure to read this before handling. Mounting Caution 1.

A B C A B C A B C A B C 1/8" 1/8" 1/4" 1/8" 1/4" 3/8" 1/4" 3/8" 1/2" 3/8" 1/2" 3/4" 1/2" 3/4" 1" Tubing Connection E 1A LQ3 Size Combination Class Fitting Style Symbol E T P U Combination 1 2 3 4 5 6 Tube Size (Inch) 1/8" x 0.086" 1/4" x 5/32" 3/8" x 1/4" 1/2" x 3/8" 3/4" x 5/8" 1" x 7/8" Style Elbow Union Tee Union Panel Union Straight Union A A A A A A Series LQ3 Dimensions Straight Male

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 12 V Body size Port size Rc Option Symbol P/A port R port B (Bracket) F (Foot) G (Pressure gauge) N (Silencer) 00 M5 00 M5 01 00 01 02 00 02 03 04 Symbol Mounting Without sub-plate M5 Without sub-plate M5 D B 1 8 Without sub-plate Base mounted 1 8 1 4

A H 2-P Port size 2-P A B H 2-M Port size 2-M Thread depth N L L K K Conduit terminal: T F (Q) 34 25 U R C G (PF) 1/2 E B A H D 2-P Port size (S) 2-M L K N.C.

Body/Exhaust Type: B (Single Unit - Port Exhaust), Nominal Nozzle Size: 10 (ø1.0), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: R (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / PNP 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch

Body/Exhaust Type: B (Single Unit - Port Exhaust), Nominal Nozzle Size: 12 (ø1.2), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 6 (12 VDC), Vacuum Sensor: R (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / PNP 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch

Body/Exhaust Type: B (Single Unit - Port Exhaust), Nominal Nozzle Size: 10 (ø1.0), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06

Body/Exhaust Type: B (Single Unit - Port Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), IO-Link compatible vacuum pressure switch: 5 (-100 to 100 kPa, w/ Unit Selection, w/Energy Saving), Connector: H (300mm Lead wire with M12 connector for IO-Link), Vacuum, V Port: 06 (ø6 One-touch Fitting, Metric), Bracket: B [With One