SMC Corporation of America
Elite Part Number Search
Search Results "ISE20B-V-P-M5-WA1"

E30 s : V g 20 Danger ~ Zone V 10 V 5000 10 15000 20 Welding Current (A) t2 SO 40 Safe 130 . ~ 20 S Zone . , .. ., , is 10 , , " 0 5000 10 15000 20 Welding Current (A) Series CD02BP High Magnetic Reid Resislance Through Hole Mount:COQ2BPO D DM-OO p 050 Hs z w o 4-" N Throu h hole 4X2-00 Counter bore Both Ends Tapped: COQ2APO -O OM-OO ~~ NOle: Female thread and rod dimensions

V 06 3/4 V Note 7) Each option is not assembled with the product, but shipped together.

Pressure Control Equipment Specifications 0 to 1 MPa Rated pressure range Output Specifications 0.1 to 1 MPa Set pressure range NPN open collector output 1.5 MPa Withstand pressure Max. 30 V, 80 mA Residual voltage 1 V or less 0.01 MPa Set pressure resolution 12 to 24 VDC, Ripple (p-p) 10% or less (with power supply polarity protection) Power supply voltage Brown DC (+) 55 mA or less (at

Pressure Control Equipment Specifications 0 to 1 MPa Rated pressure range Output Specifications 0.1 to 1 MPa Set pressure range NPN open collector output 1.5 MPa Withstand pressure Max. 30 V, 80 mA Residual voltage 1 V or less 0.01 MPa Set pressure resolution 12 to 24 VDC, Ripple (p-p) 10% or less (with power supply polarity protection) Power supply voltage Brown DC (+) 55 mA or less (at

Power supply is AC200V single phase (Note 4) Controller Forced Alarm forced stop stop ON OFF RA1 RA2 MC MC SK Driver Servo amplifier Servo motor NFB MC CNP1 L1 1-phase 200 to 230VAC CNP3 (Note 6) U 2 L2 U Motor [1] V 3 L3 V M N W 4 W 1 P1 (Note 1) P2 PE CNP2 P (Note 2) C [3] [2] D (Note 3) Encoder CN2 Encoder cable L11 L21 CN3 CN3 24VDC Forced stop EM1 DOCOM (Note 5) DOCOM DICOM (Note 5)

10%, Ripple (p-p) 10% or less (with power supply polarity protection)45 mA or lessNPN or PNP open collector 2 outputs (Selectable)80 mA28 V (at NPN output)1 V or less2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above) Note 1)Variable (0 or above) Note 1)1 to 5 V ?2.5% F.S.?1% F.S. or lessApprox. 1 k 4 to 20 mA ?2.5% F.S.?

Model MQR1-M5 MQR2-M5 MQR4-M5 MQR8-M5 MQR12-M5 Number of circuits 1 2 4 8 12 Operating fluid Air / Inert gas Seal structure Metal seal Guide structure Bearing supported Bearing supported at both ends Port size Male R1/8 Female M5 x 0.8 M5 x 0.8 Flow rate C[dm3/(s.bar)] b Cv characteristics 0.50 0.40 0.17 Lubrication Not required Min. operating pressure -100kPa Max. operating pressure 1.0MPa

In center position the flo/v P-A, B is as sholn. X X { l ) Series NVFSOO How To Order NVFs lPort size (P,A,B) OXT Y.NPIF O3T %NPTF o4T. _ IbNPIF Typ of I *2 positiqr/singlo solanoid 2 -e position/double eolgnoid l-3 posilion, dGd c6oter/doubl6 solonoid 4 -3 gooidofl extEugt centr/double solenoid 5 -A pEsilion, p.6sure crte./double solenoid oyeride 'Subbas type only.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VR Model VH Flow characteristics Pilot port size Pilot port piping location b Cv b C [dm3/(sbar)] 1 4/2 (P A/B) 4/2 5/3 (A/B EA/EB) C [dm3/(sbar)] Cv Function Port size Valve model VHS VZA2121-M5 VZA2221-M5 VZA2321-M5 VZA2421-M5 VZA2141-1-01 VZA2141

Bulkhead female union P. 77 KCE Use for transit connection of a tube and a male screw for installation of panel. 74 Series KC Self-seal Fittings M5 Half union: KCH M5 Applicable tube O.D. (mm) Effective orifice(mm 2) Weight (g) A Thread R(PT) Part No. H (Hex.)

The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple. VACUUM SWITCH, ZSE30, ZSE30A. 3 SCREEN HI PRECISION DIG PRESS SWITCH. 61.00000 lb. N63.

The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3-Screen High Precision Dig Press Switch, VACUUM SWITCH, ZSE30, ZSE30A, N63, 61 lb

URL http://www.smcworld.com -10 V to 10 V -20 mA to 20 mA for 2 hours each in direction X, Y and Z respectively (De-energized) 24 VDC Class2, 2 A 10 to 57 Hz: constant amplitude 0.75 mm p-p 57 to 150 Hz: constant acceleration 49 m/s2 0 V to 10 V 0 mA to 20 mA Content Content Content 0 V to 10 V 0 mA to 20 mA 0 V to 10 V 0 mA to 20 mA

JS20, 32, 40, 63 Center of sphere M M U U D J F B E G P A R H (mm) Max. thread depth P Center of sphere R Allowable eccentricity U Max. operating tension and compression force (N) Weight (kg) M A B C D E F G H J Model JS10-4-070 JS16-5-080 8.5 0.5 17 0.01 14.4 M4 x 0.7 9.5 12 4 7 4.7 80 4 1.5 26 12 0.5 23 19 0.02 M5 x 0.8 13.5 16 6 10 5.8 210 5 2 34.5 JS20-8-125 JS32-10-125 15.5 0.5 29.9

Specifications Model PSE530-M5 PSE531-M5 101 to 101kPa PSE532-M5 PSE533-M5 Rated pressure range 0 to 1MPa 0 to 101kPa 0 to 101kPa Proof pressure 1.5MPa 500kPa Air, Non-corrosive gas Fluid 12 to 24VDC (Ripple 10% or less) Power supply voltage Current consumption 15mA or less Output specification Analog output (1 to 5V, Output impedance: Approx. 1k) Accuracy 2% F.S. or less (within rated pressure

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8)

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: 01 (R1/8)

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: NPT1/8, Lead Wire: -, Bracket: -, Operation Manual: -

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: R1/8, Lead Wire: -, Bracket: -, Operation Manual: -

Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: -, Bracket: -, Operation Manual: -