SMC Corporation of America
Elite Part Number Search
Search Results "LEYG25LDEA-150C-R3C6173"

Series: LEY, Size: 40, Motor Mounting Position: Top Side Parallel, Motor Type: G (High Performance Battery-less Absolute, Step Motor, 24 VDC), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 40: 16mm), Stroke: 150mm, Motor Option: C (w/Motor Cover), Rod End Thread: Rod End, Female Thread, Mounting: Ends Tapped/Body Bottom Tapped, Parallel, In-line), Actuator Cable Type, Length: R3 (3m), Controller

Size: 16, Bearing Type: L ( Ball Bushing Bearing), Motor Mounting: D (In-line Type), Motor Type: Step Motor (Servo/24VDC), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 150mm, Motor Option: C (with Motor Cover), Guide Option: w/o Guide, Actuator Cable Type: R (Robotic Cable - Flexible cable), Actuator Cable Length: 3 (3m), Controller Type for (LEC, JXC): C91 (JXC91, EtherNet

Size: 16, Bearing Type: L (Ball Bushing Bearing), Motor Mounting Position: D3 (In-line; Motor Cover Direction: Top), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 150mm, Motor Option: C (w/Motor Cover), Guide Option: w/o Option, Actuator Cable Type, Length: R3 (3m), Controller: C91 (Ether Net/IPâ„¢), Mounting: 8 (DIN Rail)

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~70, Operating Pressure(MPa): 0.05~1, Cushion: Air cushions on both sides + with damper cushions, Specification: Without

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~70, Operating Pressure(MPa): 0.05~1, Cushion: Air cushions on both sides + with damper cushions, Specification: Built-in

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~70, Operating Pressure(MPa): 0.05~1, Cushion: Air cushions on both sides + with damper cushions, Specification: Built-in

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~70, Operating Pressure(MPa): 0.05~1, Cushion: Air cushions on both sides + with damper cushions, Specification: Without

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Support bracket: None, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: None, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: None, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: None, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: None, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: None, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: M9B, Lead Wire Length(m): 3, The number of the switches: 2, Type of Auto

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead Wire Length(m): N/A, The number

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead Wire Length(m): N/A, The number

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead Wire Length(m): N/A, The number

Series: LEFS (Ball Screw Drive), Accuracy: Basic Type, Size: 32, Motor Mounting Position: In-line, Motor Type: T7 (200W Output, Absolute Encoder), Lead: B (LEFS25, 6mm; LEFS32, 8mm; LEFS40, 10mm), Stroke: 150mm, Motor Option: w/o Option, Auto Switch Mounting Bracket: C (w/1pc, Included), Grease Application: with, Positioning Pin Hole: Housing B, Bottom, Cable Type: R (Robotic Cable, Flexible

Series: LEFS (Ball Screw Drive), Accuracy: Basic, Body Size: 25, Motor Mounting Position: In-line, Motor Type: G (High Performance, Battery-less Absolute), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32: 8mm, Size 40: 10mm), Stroke: 150mm, Motor Option: w/o Option, Auto Switch Mounting Bracket: C (with, Includes 1 mounting Bracket), Grease Application: With, Positioning Pin Hole: Housing B

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting