Nozzle Diameter: 18 (ø1.8mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: 11 (One-touch Fitting ø3/8"), VAC: 13 (One-touch Fitting ø1/2"), EXH: 13 (One-touch Fitting ø1/2")

Nozzle Diameter: 20 (ø2.0mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: 11 (One-touch Fitting ø3/8"), VAC: 13 (One-touch Fitting ø1/2"), EXH: 13 (One-touch Fitting ø1/2")

Nozzle Diameter: 20 (ø2.0mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: 11 (One-touch Fitting ø3/8"), VAC: 13 (One-touch Fitting ø1/2"), EXH: 13 (One-touch Fitting ø1/2"), Accessories: N (w/o Bracket, w/o Silencer)

Nozzle Diameter: 20 (ø2.0mm), Vacuum Pressure: S (-90 kPa), SUP: 11 (One-touch Fitting ø3/8"), VAC: 13 (One-touch Fitting ø1/2"), EXH: 13 (One-touch Fitting ø1/2")

Nozzle Diameter: 18 (ø1.8mm), Vacuum Pressure: S (-90 kPa), SUP: 11 (One-touch Fitting ø3/8"), VAC: 13 (One-touch Fitting ø1/2"), EXH: 13 (One-touch Fitting ø1/2")

Nozzle Diameter: 18 (ø1.8mm), Vacuum Pressure: S (-90 kPa), SUP: 11 (One-touch Fitting ø3/8"), VAC: 13 (One-touch Fitting ø1/2"), EXH: 13 (One-touch Fitting ø1/2"), Accessories: N (w/o Bracket, w/o Silencer)

This may damage the pressure sensor, leading to malfunction. 25.5 Brown OUT(+) Load PS1000/PS1100/PS1200 + Main circuit of switch 12 to 24 VDC AIRCHECKER + PS1000-R06L 13 PRESS. -0.10.45MPa {-14.6kgf/cm2} MADE IN JAPAN G Thank you for purchasing the SMC PS1000/PS1100/PS1200 Series Air Checker: Electronic Pressure Switch.


Recommended solenoid valve size:
PA3□13, PAP3313, or PAF3413 with a C value of 0.55 (CV value of 0.13) or higherEx.) VQZ14□0 (exhaust center) + PA5□13: C value of 1.1 (CV value of 0.28) or higherEx.)

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

SeriesNCA1 Air Cylinder: Standard Type Double Acting, Single Rod Maintenance Parts 150 to 400 Construction 15 17 13 14 16 Seal Kit Parts List No. 13 14 15 16 17 Description Cushion Seal Rod Seal Piston Seal Cushion Valve Seal Cylinder Tube Gasket Material NBR NBR NBR NBR NBR Kit no.s can be found on the next two pages. *Call or email us at sales@smcpneumatics.com for request.

Pad typePad diameter Pad diameter (Symbol) Pad type B04 B06 07 B08 06 05 03 U (Flat) C (Flat with rib) UT (Thin flat) B (Bellows) Dimensions: Pad Unit ZP2-05UT ZP2-06UT ZP2-B06B ZP2-B08B ZP2-03U ZP2-B04U 7 7 7 7 7 7 12 12 12 12 13 13 4 4 0.5 0.8 0.3 0.3 0.8 1.2 1.6 1.6 2.5 2.5 5 6 4 3 4.7 3.3 4.7 6 3.5 8 9 7 9 10 ZP2-B06C ZP2-07C ZP2-B08C Adapter Mounting Dimensions 7 7 7 If an adapter will

SeriesNCA1 Air Cylinder: Standard Type Double Acting, Single Rod Maintenance Parts 150 to 400 Construction 15 17 13 14 16 Seal Kit Parts List No. 13 14 15 16 17 Description Cushion Seal Rod Seal Piston Seal Cushion Valve Seal Cylinder Tube Gasket Material NBR NBR NBR NBR NBR Kit no.s can be found on the next two pages. *Call or email us at sales@smcpneumatics.com for request.

SI Unit: ZEN (EtherNet/IP), Input Block Stations: 13 (1 Station/M8: 4 Inputs 3 Pins), Input Block COM: +COM, Stations: 13 Stations, SUP/EXH Block Mounting: B (Both Sides 2~20 Stations), Pilot: Internal Pilot, A, B Port: C4 (ø4 One-touch Fitting), Mounting Method: D0 (DIN Rail Mount w/o DIN Rail)

SI Unit: ZEN (EtherNet/IP), Input Block Stations: 13 (1 Station/M8: 4 Inputs 3 Pins), Input Block COM: +COM, Stations: 13 Stations, SUP/EXH Block Mounting: B (Both Sides 2~20 Stations), Pilot: Internal Pilot, A, B Port: C6 (ø6 One-touch Fitting), Mounting Method: D0 (DIN Rail Mount w/o DIN Rail)

SI Unit: QW (DeviceNet), Input Block Stations: 13 (1 Station/M8: 4 Inputs 3 Pins), Input Block COM: N (-COM), Stations: 13 Stations, SUP/EXH Block Mounting: B (Both Sides 2~20 Stations), Pilot: S (Internal Pilot, Built-in Silencer), A, B Port: C4 (ø4 One-touch Fitting), Mounting Method: Direct Mounting, US Option: X160US (Preferred US Option for DeviceNet Type)

SI Unit: QW (DeviceNet), Input Block Stations: 13 (1 Station/M8: 4 Inputs 3 Pins), Input Block COM: N (-COM), Stations: 13 Stations, SUP/EXH Block Mounting: B (Both Sides 2~20 Stations), Pilot: S (Internal Pilot, Built-in Silencer), A, B Port: C4 (ø4 One-touch Fitting), Mounting Method: D0 (DIN Rail Mount w/o DIN Rail), US Option: X160US (Preferred US Option for DeviceNet Type)

Type: 10S (Side Ported), SI Unit Specification: NA (PROFIBUS DP - 32 Outputs - Connector M12), SI Unit Output Polarity: Positive Common, NPN or w/o SI Unit, Valve Stations: 2 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block: R (External Pilot), A, B Port Size: C6 (ø6 One-touch Fitting), Mounting: D (DIN Rail Mounting w/o Name Plate), DIN Rail Option: 13 (for 13 Stations; Longer

Stations: 12 Stations, Port Size: N7 (ø1/4" One-touch Fitting), S Kit: SEA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Polarity: N (Negative Common), Option 1: D (DIN Rail), DIN Rail Length: 13 Stations (for 13 Stations; Longer Rail than Total Length of Specified Valve Stations), Option 2: S (Built-in Silencer, Direct Exhaust)

Stations: 12 Stations, Port Size: C4 (ø4 One-touch Fitting), S Kit: SEA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Polarity: N (Negative Common), Option 1: D (DIN Rail), DIN Rail Length: 13 Stations (for 13 Stations; Longer Rail than Total Length of Specified Valve Stations), Option 2: R (External Pilot)

Stations: 12 Stations, Port Size: C6 (ø6 One-touch Fitting), S Kit: SKA (IO-Link - 32 Outputs - Connector M12), SI Unit Polarity: N (Negative Common), Option 1: D (DIN Rail), DIN Rail Length: 13 Stations (for 13 Stations; Longer Rail than Total Length of Specified Valve Stations), Option 2: NS (N + S)